Part Number Hot Search : 
U1000 01456 MTA106F 08783 256TI HER805T MX7537SQ 2SA1944
Product Description
Full Text Search
 

To Download 3291 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CLAMP ON HiTESTER 3291 CLAMP ON LEAK HiTESTER 3293
Clamp Testers
The World's First Flip Clamp!
For leak and load current: 3293 (0.06mA to 1000A) Double the functionality For load current: 3291 (0.06A to 1000A)
Stylish pocket-size design Backlit display with automatic reverse feature Filter
Load current
3291
Leak and load current
3293
10uA Resolution
2
Flip-type clamp on design delivers the ease-of-use demanded by field technicians
Flip-down display keeps readings in easy view whether the target wire is up high or down low
Equipped with an innovative display that flips down for easy visibility, the 3291 and 3293 are designed for efficient measurement of indoor wiring in a variety of environments, from factories, buildings, and offices to residences.
Easy to read means easy to use
D isplay rot ates f reely through 18 0 to keep measurements in view.
Easy measurement of wires on ceilings
Flip angle: 180 Easy to see, even when held up high Measurement reading reverses automatically when the display is flipped open to ensure readability. Backlight lets you read measurements in dim locations
* Push and hold for 2 seconds to activate * Backlight goes out automatically after 15 seconds
Display can also be reversed manually with the press of a button.
Easy to see, even when held down low
New clamp design is easier to attach
Slim clamp with a wide aperture attaches easily, requiring only 12.5 mm of space between wires.
Unmatched ease of use
Clamp meter turns on automatically when the clamp is opened so you can begin taking measurement immediately.
Open Jaws to Power On
Automatically turns off 1 minute after input falls to 0A following measurement. (Can be manually disabled.)
Slim core opens wide for easier clamping.
3291
8mm
3293
11mm
Up to 30 mm in diameter
Up to 24 mm in diameter
Sometimes it's easier to clamp the target wire at an angle.
3
Extensive current measurement functions
True RMS lets you measure even distorted currents accurately
True RMS ensures accurate measurement, even of distorted load and leak currents Why does the same current yield different readings?
Use with 3-phase 4-wire 440V lines
3291: CAT III 600 V (CAT IV 300 V) 3293: CAT III 300 V
Averaging-type clamp on current meter
Measure leak and load current with the 3293
The 3293 features 6 ranges from 30 mA to 1000A, offering 5% rdg 5 dgt measurement accuracy of 1mA leak currents. Easy-to-use auto range feature
3293 Leak current easurement 30.00mA 300.0mA Leak current easurement 6.000A Load current measurement 60.00A 600.0A 1000A Range 3291 Range
Inverters, office equipment, AC adapters most load current waveforms are distorted. Current meters that display average True RMS clamp on rectified RMS values does not allow you to current meter obtain accurate RMS measurements.
Filter out noise
The 3291 and 3293 incorporate a switchable high-frequency noise filter. When activated, this filter rejects frequencies of 180 Hz and above to enable measurement approximating the filter characteristics of an earth leakage circuit breaker (ELCB). Get the maximum value of fluctuating current readings
Load current measurement 60.00A 600.0A 1000A
3293 Actual Size
Push and hold for 2 seconds to activate filter
Filter on
Measure fluctuating currents with the peak hold feature
The 3291 and 3293's peak hold feature (with bar graph hold) lets you capture peak values for currents that fluctuate due to load variability. Easy measurement of the peak value of a fluctuating current.
*Holds the peak value for data updated approximately 2 times/second.
Current (A) Peak value display
Time
Peak value is held on the bar graph.
Loop a wrist strap through the small opening to help keep the instrument from being dropped
4
Pocket Size Clamp On Design
Fits perfectly into a shirt pocket. Compact design for superior portability
3291, 3293 Specifications (accuracy at 23C5C (73F9F), 80% RH or less)
3291
Load
Measurable conductor size Rectification Max. rated voltage to earth Measurement Range *Auto Range switching * *Zero-suppress at 5 counts Accuracy
filter ON: fc=180Hz
Leak and load
o24mm (0.94")max. True RMS AC300Vrms 30mA/300mA/ 6A/60A/600A/1000A
3293
o30mm (1.18")max. AC600Vrms 60A/600A/1000A
3291 Actual Size
Guaranteeed Accuracy Period Accuracy Guaranteed Measurements Crest factor Response Time Display Refresh Rate Temperature Coefficient Effect of Conductor Position Effect of External Magnetic Field Other Functions Usage Environment Storage Environment Standards Rated Voltage and maximum rated power Power Supply and max. continuous use Dimensions and mass
1.5%rdg. 5dgt. (50Hz to 60Hz), 5%rdg. 5dgt. (1mA to 2.70mA) filter OFF: 2.0%rdg. 5dgt. (45 to 66Hz), 3.0%rdg. 5dgt. (66 to 400Hz) (Add1%rdg. for when using 60A on the 3293) 1 Year (or opening and closing of the sensor 10,000 times) Minimum 1.00mA Minimum 5.40A (Add1%rdg. for readings of 0.270 to 0.540A ) 2.8 max (1.6 max when current exceeds 600A) Max. 1.5s (Refers to time required to achieve 90% of accuracy specifications) Approx. 2 times/second (Bar graph: Approx. 4 times/second) Add (0.05 x accuracy specifications)/C (at 0C to 40C) within 0.1% (at or below 6A range) within 5.0% within 5.0% (at or below 60A range) Max 7.5mA (within a 400A/m not defined magnetic field, at or below 6A range) Display hold, maximum value hold (hold bar graph position), reversible LCD display, backlight, auto power off, auto power on when jaws are open, battery level indication 0C to 40C/32F to 104F, 80%rh max. (no condensation) -10C to 50C/14F to 122F, 80%rh max. (no condensation) EN61010-2-032 EN61010-2-032 Type A current sensor, Type A current sensor, CAT III 600V, CAT IV 300V, EN61326 CAT III 300V, EN61326 DC3V, 25mVA Button type lithium battery (CR2032) x 1, Approx. 10 hours (continuous, no load) 50Wx136Hx26Dmm, 90g 50Wx130Hx26Dmm, 120g 1.97"x 5.35" H x 1.02" D, 3.2 oz. 1.97"x 5.12" x 1.02", 4.2 oz.
Convenient portable case
Included soft case protects the instrument and attaches conveniently to your belt.
Soft case protects the instrument inside toolboxes.
Carrying Case Model 9757 (included) Inside toolboxes Attaches to belt
0
6.00mA
5
Bundled Accessories: Carrying Case 9757 x 1, Wrist strap x 1, Button type lithium battery (CR2032 - test use only) x 1, Instruction Manual x 1, Basic Operation Sticker x 1
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
0
10
6.00
5 10
15 20
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: info-sh@hioki.cn
DISTRIBUTED BY
HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: info-bj@hioki.cn
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.cn
0 5 10 15 20
All information correct as of Jul. 12, 2007. All specifications are subject to change without notice.
6.00mA
0
6.00mA
3291sE1-77M-20P Printed in Japan
5 10 15 20


▲Up To Search▲   

 
Price & Availability of 3291

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X